Micro Encoder Assembly

Micro Encoder Assembly

Page 5
 
Locate the airspeed sensor, altitude sensor, clear tubing, brass fittings and crimp clamps. From the tubing cut four pieces, 3.2", 2.4", 1.2", and 1.1". assemble the sensors and brass fittings according to figure 24 in the manual. Crimp all the tubing clamps. Set aside for later.
Gather the two sort cards, two packs of matched resistors and the two PC Boards. Following the manual insert all the resistors into the A/D board. Solder and Clip the leads. Open 1 package of matched resistors at a time insert and solder before opening the second package. Install the little blue trimpot followed by the capacitors. Solder and clip.
 
Install all the radial type capacitors and the four large polypropylene capacitors. Solder and clip. There are a few transistors in the black antistatic box, they come next. Get out your magnifying glass again as the printing is extremely small.